l
(%)
out
HO
110%
100%
90%
80%
60%
40%
20%
0
0
2
Illustration 6.8 Derating of I
Enclosure Types B3 and B4, using 60° AVM in High overload
6
6
mode (160% over torque)
l
out
NO
110%
100%
90%
80%
60%
40%
20%
0
0
Illustration 6.9 Derating of I
Enclosure Types B3 and B4, using 60° AVM in Normal
overload mode (110% over torque)
SFAVM - Stator Frequency Asyncron Vector Modulation
I
(%)
out
HO
110%
100%
80%
60%
40%
20%
0
0
2
Illustration 6.10 Derating of I
Enclosure Types B1 and B2, using SFAVM in High overload
mode (160% over torque)
74
45 C
50 C
f
sw
4
6
8
10
12
14
16
for different T
out
AMB, MAX
(%)
6
8
10
16
2
4
12
14
for different T
out
AMB, MAX
4
6
8
10
12
14
for different T
out
®
VLT
AutomationDrive FC 301/FC 302 Design Guide, 0.25-75 kW
110%
100%
80%
B3 & B4
60%
o
40%
o
20%
0
0
(kHz)
Illustration 6.11 Derating of I
Enclosure Types B1 and B2, using SFAVM in Normal overload
mode (110% over torque)
for
110%
100%
90%
80%
B3
B4
60%
40%
o
45 C
o
20%
50 C
o
55 C
f
(kHz)
sw
Illustration 6.12 Derating of I
Enclosure Types B3 and B4, using SFAVM in High overload
mode (160% over torque)
for
110%
100%
90%
80%
B1
60%
B2
45°C
40%
50°C
20%
55°C
f
(kHz)
sw
Illustration 6.13 Derating of I
16
Enclosure Types B3 and B4, using SFAVM in Normal overload
for
AMB, MAX
mode (110% over torque)
MG33BF02 - Rev. 2013-12-20
I
(%)
out
NO
2
4
6
8
10
12
for different T
out
l
(%)
out
HO
o
45 C
o
50 C
0
0
2
4
6
8
10
12
for different T
out
l
(%)
out
NO
o
45 C
o
50 C
0
0
2
4
6
8
10
12
for different T
out
B1
B2
45°C
50°C
55°C
f
(kHz)
sw
14
16
for
AMB, MAX
B3
B4
f
(kHz)
sw
14
16
for
AMB, MAX
130BB832.10
B3
B4
f
(kHz)
sw
14
16
for
AMB, MAX