Display Count: Air Detected at Power On

7-002-049
AIR CNT:P:T1
7-002-050
AIR CNT:P:T2
7-002-051
AIR CNT:P:T3
7-002-052
AIR CNT:P:T4
Use this SP to display the number of times air was detected by the air sensor a print
head tank at power on.

Display Count: Air Detection Frequency

7-002-055
AIRLEAKCHK:TH
7-002-056
AIRLEAKCHK:TIM
7-002-057
AIRLEAKCHKCNT:H1
7-002-058
AIRLEAKCHKCNT:H2
-055:
Use this SP to specify the threshold for displaying SC282-11-13 (The default is to
17).
-056:
Use this SP to specify the period over which to count the number of air detection
(The default is 10 days).
-057, -058:
Use this SP to display the number of air detection in the specified period.

Display Count: Automatic Cleanings Between Page Prints

7-002-061
ACL CNT:P:H1
7-002-062
ACL CNT:P:H2
Use this SP to display the number of automatic print head cleanings between page
prints while print jobs were executing.
Print Head Tank 1 (Cyan)
Print Head Tank 2 (Black)
Print Head Tank 3 (Yellow)
Print Head Tank 4 (Magenta)
Threshold
Time/Date
Print Head 1 (C / K)
Print Head 2 (Y / M)
Print Head 1 (C / K)
Print Head 2 (Y / M)