Service Call Code Tables - Ricoh BRG-P1 Field Service Manual

Table of Contents

Advertisement

6. Troubleshooting
• Automatic rebooting can be set to on/off in SP5-875-001 (Default: on).

Service Call Code Tables

SC
Pattern
20000
D
SC
Pattern
20200
D
SC
Pattern
20211
D
SC
Pattern
1
20212*
D
SC
Pattern
1
20213*
D
210
Error Name / Detection Criteria / Major Cause / Solution
The maintenance motor is not in the home position.
Turn the main power switch off and then back on.
Error Name / Detection Criteria / Major Cause / Solution
Failure to form negative pressure in the maintenance unit (while assessing the
negative pressure in the tank)
Turn the main power switch off and then back on.
Error Name / Detection Criteria / Major Cause / Solution
Failure to form negative pressure in the maintenance unit (air leak) (Tank 1
error)
Error Name / Detection Criteria / Major Cause / Solution
Failure to form negative pressure in the maintenance unit (air leak) (Tank 2
error)
Turn the main power switch off and then back on.
Error Name / Detection Criteria / Major Cause / Solution
Failure to form negative pressure in the maintenance unit (air leak) (Tank 3
error)
Turn the main power switch off and then back on.

Advertisement