Maintenance

300 Hour / Yearly Interval

Replace engine air cleaner filter element.

Check inner filter element.

600 Hour Interval

Replace air cleaner inner filter element.

1500 Hour / Yearly Interval

Change Hydraulic Oil / Filter

Hydraulic tank capacity is 6 gal US. Clean the tank surface prior to
changing oil. Factory fill hydraulic oil is ISO HVI 46
When adding hydraulic oil, always pump new oil through a 10
micron absolute filter to ensure oil cleanliness.
Use remote drain hose to drain oil into an approved container.
Change return filter element.
Pump new oil through a filter to refill tank. Refer to table on page 40
for proper oil.
Refill so oil level is to the bottom of the upper sight glass.
After filling hydraulic system, start machine and operate in a safe
location forward and back for a few moments. Shut off engine and
recheck level. Adjust if required.
Be careful when changing oil. Hot oil can burn unprotected skin.

Change Oil in Gearbox

Remove gearbox mount assembly from machine to drain oil into an
approved container. Oil is drained by removing vent assembly from
top of gearbox and inverting assembly.
Reinstall the gearbox mount assembly.
Remove oil level plug from side of gearbox (arrow). Fill through
opening on top of gearbox to level where oil just starts to flow out of
side hole (approx. 475ml). Use 80W90 gear oil or equivalent.