Figure 5-14 Detecting smoke
(1) Smoke compartment
----End

5.7.2 Commissioning a Smoke Sensor

5.7.2.1 Commissioning a Smoke Sensor (connected to the AI/DI port on the
ECC800)
If a smoke sensor is installed, perform the following steps to configure it.
Context
Procedure
Step 1 Set smoke sensor parameters.
1.
2.
3.
4.
Issue 02 (2019-02-28)
If the sensor is prefabricated, only check its settings.
The actual value prevails. Only the method of the parameter settings is described.
In this example, the smoke sensor is connected to the AI/DI_1 port on the ECC800.
Log in to the ECC800 WebUI as an administrator.
Choose Monitoring > System > ECC800 > Running Parameters > AI/DI_1 Port
Settings.
Set AI/DI_1 sensor to Enable, and click Submit.
Set AI/DI_1 sensor name to Smoke sensor.