Programming Codes

Code One Print Options

Function
Code One code control
ASCII
[ESC] [EM] 1 <f> <v>
Hexadecimal 1BH 19H 31H <f> <v>
Decimal
<27> <25> <49><f> <v>
IPCL
None
Description This command alters the way Aztec barcodes are generated and printed.
Where
f = Feature to control and v = the value of the feature.
f = W 57H, 87D
f = M, 4DH, 77D
f = H, 48H, 72D
f = G, 47H, 71D)
f = P, 50H, 80D
f = F, 46H, 70D
Page 156
Set the minimum element width.
v = 1-10, 6 is the default and height.
A width of 1 may be unreadable.
It the barcode will not fit in the print zone, the printer will
automatically reduce the width until the barcode will fit. If
the barcode will not fit at a width of 1, the printer will not
print the barcode.
Code One Matrix Size. 1-10 are accepted. 0 – Auto
Size 1-8 are 1A – 1H and 9 - 10 allow other shapes.
Blank Space between the barcode and the following data
Default 8
GS1 Mode. (See General description above)
If in GS1 mode the symbol start with an FNC1 and that the
compression is slightly altered. GS1 data formatting and
compaction are active and the input must follow the GS1
rules.
HRI Position
f =0 – Off, f = 1 - Top, f =2 - Bottom, f =3 - Both
HRI Font
f = 0 Medium, f=1 Larger, f- 2 Smaller (Note: Fonts may be
redefined by using the change legacy font command.)
Rev A