Extended Printer Control
T480
Function
Read and Return Totals
ASCII
[ESC] ~ T <n>
Hexadecimal 1BH 7EH 54H <n>
Decimal
<27> <126> <84> <n>
Description This command returns the current statistics for parameter n. The value
returned will be ~T<n> with the next 4 bytes being an unsigned integer. For example:
[ESC]~T<1> Request cover open count
Returns:
~T<1><0><0><1><100> or 256 + 100 or 356 cover opens
Values of n
Request:
0
Not Used
1
Not Used
2
Not Used
3
Cover Opens
4
Paper Outs
5
Line Feeds
6
Characters Printed
7
Cash Drawer
8
Not Used
9
Init Requests
10
Auto Cutter Faults
11
Over Temperature
12
Auto Cutter Re-home
13
Not Used
14
Not Used
15
Missed TOF (if equipped)
Page 236
16
Configuration Faults
17
Cash Drawer Opens
18
Auto Cutter Cycles
19
Not Used
20
Not Used
21
Standby Cycles
22
Power Up Cycles
23
Fault Resets
24
Power On Time (Min.)
25
System Active Time (Min.)
26
Error Vectors
27
Flash File Faults
28
USB Watch Dog Count
29
FAT Flash Erase Cycles
30
Ext Flash Erases
31
System Memory Faults
Rev A