Upgrading Cache
Memory for the
E5400
Controller-Drive
Trays
Chapter 2: Upgrading Trays in the Storage Array
7.
Using the LEDs and the storage management software, check the status of the
trays in the storage array.
8.
Does any component have a Needs Attention status?
Yes – Click the Recovery Guru toolbar button in the Array Management
—
Window, and complete the recovery procedure. If the problem is not
resolved, contact your Technical Support representative.
No – Go to step 13.
—
9.
Remove the antistatic protection.
10. Gather support data about your updated storage array by using one of these
methods:
SANtricity ES
Command line interface
Before you start this procedure, gather antistatic protection, cache memory DIMMs,
and cache backup memory devices. Perform each of the following tasks in order.
1.
Choose the applicable task to remove the controller canisters:
Remove the controller canisters from the E5412 or E5424 controller-drive
—
tray.
Remove the controller canisters from the E5460 controller-drive tray.
—
The remaining tasks in this section are the same for the E5412, E5424, and
E5460 controller-drive trays.
2.
Upgrade the cache memory DIMM.
3.
Upgrade the cache backup memory device.
4.
Reinstall the controller canisters from the controller-drive tray.
5.
Turn on power to the controller-drive tray.
From the Array Management Window toolbar, select
Monitor >> Health >> Collect Support Data. Then
name and specify a location on your system where
you want to store the support bundle.
Enter the following command on the command line:
save storageArray supportData
This command gathers comprehensive support data
about the storage array. For more information about
this command, refer to Command Line Interface and
Script Commands Programming Guide. Running this
command can temporarily impact performance on
your storage array.
39
Need help?
Do you have a question about the InfiniteStorage 4000 Series and is the answer not in the manual?
Questions and answers