Dampened Compensated Pvb With Ls A/B - Danfoss PVG-EX 32 Technical Information

Proportional valve group
Table of Contents

Advertisement

Technical Information
PVG-EX 32 Proportional Valve Group
PVB Basic Modules

Dampened compensated PVB with LS A/B

52 |
©
Danfoss | June 2019
The compensated PVB is intended for controlling a work function where the function behavior in terms
of flow and pressures requires independence on the load pressure of other functions used
simultaneously. The dampening of the compensator reaction will slow down the system thereby
removing instability. The integrated LS
the A/B-ports individually.
The dampened compensated PVB with LS A/B features:
Integrated LS shuttle network
Integrated compensator
Integrated adjustable LS
A/B
External LS
port connection
A/B
Optional shock/anti-cavitation valve facility (PVLP)
Dampened compensated PVB with LS A/B schematic
T P LS
1
0
LS
B
LS
A
Technical specification for A/B-port
Max. continuous pressure
350 bar [5076 psi]
*
With turbo function spool @ max rated flow of 130 l/min is possible
Parameter
Minimum
Fluid temperature
-30°C [-22°F]
Fluid viscosity
4 mm2/s [39 SUS]
Fluid cleanliness
23/19/16 (according to ISO 4406)
Operating temperature
Ambient: -30 to 60°C [-22 to 140°F]
relief valve is used to limit the maximum work port build-up on
A/B
pressure relief valves
2
A
B
Max. intermittent pressure
420 bar [6090 psi]
Recommended range
30 to 60°C [86 to 40°F]
12 to 75 mm2/s [65 to 347
SUS]
*
Max. rated flow
125 l/min [33 US gal/min]
Maximum
90°C [194°F]
460 mm2/s [2128 SUS]
BC290860493426en-000103

Advertisement

Table of Contents
loading

Table of Contents