Magnum Energy ME-MR Series Owner's Manual page 29

Inverter remote control
Table of Contents

Advertisement

Overtemp appears on the LCD and
the FAULT (red) LED is on. The INV
(green) LED's is off.
Figure 5-13, Overtemp Fault
Overtemp – This fault message indicates the inverter/charger has shut
down because the internal power components (FET's and/or Transformer)
have exceeded their safe temperature operating range. When the unit has
cooled down, it will automatically restart and continue operation.
Remedy: If the fault occurs while inverting, reduce the load on the
inverter; if it occurs while charging, turn down the charge rate. If this
fault happens often, ensure the inverter is not in a hot area, has proper
ventilation and the cooling fans inside the inverter are working.
AC Ovrld appears on the LCD and
the FAULT (red) LED is on. The INV
(green) LED's is off.
Figure 5-14, AC Overload Fault
AC Overload - This fault message displays when the AC load on the inverter/
charger's output has exceeded the inverters AC current protection limits. If the
overload condition lasts for less than 10 seconds, the unit will automatically
restart and resume operation. However, if the overload occurs more than 10
seconds, the unit will shut down and will require a manual restart.
Remedy: This fault usually occurs because the connected AC loads
are larger than inverter's output capacity, there is a wiring short on
the output or the output wires are incorrectly wired. Once the AC
loads are reduced or the output wiring is corrected; the inverter can
be restarted after a manual restart has been accomplished.
©2009 Magnum Energy Inc.
Operation
E R R O R!
O ve rte m p
E R R O R!
A C O vrld
27