Ethernet Connection Fault Management
Table
Table 240
(1 of 2)
208
240
shows the proactive delay session output fields.
Y1731 proactive delay session – show field Descriptions
Label
Description
Domain
Displays the domain of the Y1731 proactive session.
Association
Displays the association of the Y1731 proactive session.
Mep
Displays the Maintenance association End Point of the Y1731 proactive session.
Session
Displays the session id of the Y1731 proactive session.
Test type
Type of the Y1731 proactive session. This will be two-way-delay.
Admin status
Displays the admin status. (Enabled or disabled).
Priority
Displays the priority of the Y1731 proactive session.
Period
The value of period specifies the time to wait between the transmission of one OAM
request and the next for this Y1731 proactive session.
Peer Mac Addr
Displays target unicast MAC address for the Y1731 proactive session.
Interval-status
The object indicates the validity of the corresponding PM data. It is set to valid when the
PM data is complete and valid and set to invalid when the PM data is incomplete or
invalid.
Elapsed-time
The amount of time, measured in seconds that has elapsed since the beginning of the
interval.
Measured-time
The amount of time, measured in seconds that statistics for this entry have been
actually counted for the interval.
duration except in a situation
be collected for this test for some reason.
Valid-Intervals
The number of previous 15 min intervals for which valid data was collected for this test.
PDU Sent
The object indicates the number of PDUs sent.
PDU Received
The object indicates the number of PDUs received.
PDU Discarded
This object indicates the number of DMR PDUs discarded by this MEP. This will be
increment for every invalid DMR received from the Peer.
Delay(us)
The value of minimum delay indicates the minimum amount of time, measured in
microseconds, from when the test-frame was transmitted to the time it was received
Round trip
minus the local processing time taken by the remote system, and within the delay test
Min/Avg/Max
duration of 15 Minutes.
The value of average delay indicates the average amount of time, measured in
microseconds, from when the test-frame was transmitted to the time it was received
minus the local processing time taken by the remote system, and within the delay test
duration of 15 Minutes.
The value of maximum delay indicates the maximum amount of time, measured in
microseconds, from when the test-frame was transmitted to the time it was received
minus the local processing time taken by the remote system, and within the delay test
duration of 15 Minutes.
3HH-11982-AAAA-TQZZA
"FD 100/320Gbps NT and FX NT IHub System
Basics, Management and OAM Guide"
This value
will be the same as the elapsed
where
performance monitoring data could not
Issue: 10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

73307360

Table of Contents