Send Configuration - FAG Detector III Manual

Hide thumbs Also See for Detector III:
Table of Contents

Advertisement

To activate the automatic adjustment for one characteristic value proceed as
follows:
· Select the characteristic value.
· Enter the main alarm adjustment as a factor of the average value.
· Enter the pre-alarm adjustment as a percentage (less than 100).
or:
· Click Recommended to set the values recommended by Trendline.
The values suggested by Trendline for the automatic adjustment of
alarm values are based on empirical values used by FAG Industrial
Services GmbH. As entirely different settings may be required
depending on the properties of the components being monitored
these must be regarded purely as suggested values which are
therefore non-binding. In all cases the user is responsible for
selecting appropriate alarm values.
Select the machine class for the characteristic value ISO 10816.

3.4.10 Send configuration

You can send a configuration or a part of a configuration to the Detector. For that,
follow the sequence below:
· Select a machine in the tree.
· Connect the connector to the serial interface using the data cable.
· Switch on the detector.
· Click on Detector > Send configuration in Trendline 3 software or click on
.
Now, the configuration for the machine selected including all measuring points is
sent to the Detector. If you want to send a complete configuration, you would have
to select the configuration in the tree (in the example in paragraph 3.3.1 this would
be "Cement Plant 1") prior to sending the data. It is even possible to send one
measuring point. This facility is mostly used for test purposes.