3.4 Setting up configuration

3.4.1 Enter system tree
Each configuration is subdivided into three levels, e.g. section – machine –
measuring point.
Setting up configuration elements
In order to create a new configuration, carry out the following steps:
· Click on System > New item (or on
· Name the entry, e.g. "Cement Plant 1".
· Add the new sub-entry by clicking on System > New sub-item or click on
That way, you add a new section to the configuration. Name that e.g. "Section
1".
· Exactly as with the section, add another machine ("Machine 1") and a new
measuring point ("Measuring Point 1") by following the sequence via New sub-
item.
Moving or copying configuration elements
You can only move configuration elements if the target is on a higher level, i.e. you
can
· move or copy a measuring point (level 3) to another machine (level 2), and
· move or copy a machine (level 2) to a different section (level 1).
If the target already contains sub-elements, the moved/copied
element is always appended to the end of the list.
Moving an element
· Left-click on the element, keep the mouse button pressed, and drag the element
onto the target element.
· Release the mouse button to insert the element.
Copying an element
· Left-click on the element while pressing the CTRL key, keep the mouse button
and CTRL pressed, and drag the element onto the target element.
· Release the mouse button and CTRL to copy the element.
or:
· Right-click on the element and select Copy.
· Right-click on the target element and select Paste.