Dispensing
throughput
(D1 to D13)
Dispensing
correction factor
(D1 to D13)
The throughput of the connected dispenser pumps can be set from
0 ml/min to 9999 ml/min in 1 ml/min steps.
Access the following content:
Supervisor level Settings
Dispensing throughput
Dispensing correction factor
Select "Dispensing throughput".
The following will appear in the display:
Settings
Dispensing throughput
Dispenser pump 1
:
Dispenser pump 2
:
Options:
– No
– 1 to 9999.0 ml/min
The correction factor can be used if an adjustment is made to the
liquid dispensing. If, for example, the dispensing agent for dispenser
pump D1 were altered (to a higher concentration), a quick adjustment
can be made with the correction factor.
Calculate the correction factor using the following formula:
Correction factor D1 =
Access the following content:
Supervisor level Settings
Dispensing correction factor
Dispenser level reminder
Select "Dispensing correction factor".
Settings
Dispensing correction factor
Dispenser pump 1
: 1,00
Dispenser pump 2
:
You have the following options:
– 2
– 1.99 to 0.01
Once you exit the supervisor level, the new dispensing amounts are
used in the programmes but the programming is not changed.
6000,0
ml
/
min
No
new quantity dispenser pump D1
current quantity dispenser pump D1
1,00
Programming
159