Dispensing Throughput (D1 To D13) - Miele PW 413 Operating And Installation Instructions

Table of Contents

Advertisement

Settings option
96
Dispensing calibration  Dispensing pump 1
t:
V:
100 ml
-
OK
+
Press multifunction button 0/1.
Stop the pump by pressing button 0/1, or the pump will stop auto-
matically after 60 seconds.
Measure the required amount into the measuring vessel.
Dispensing calibration  Dispensing pump 1
V:
100 ml
t:
-
OK
Enter the amount measured in field "V:".
The throughput P is calculated in ml/min. by the controls.
Press the "Save"  button.
The measured value is assigned to the pump.
Reattach the hose.

Dispensing throughput (D1 to D13)

The throughput of the connected dispenser pumps can be set from
0 ml/min to 9999 ml/min in 1 ml increments.
Access the following content:
Supervisor level
 Settings
Dispensing flow rate
Dispensing correction factor
OK
Select "Dispensing throughput".
The following will appear on the display:
Settings
 Dispensing flow rate
Dispensing pump 1
: 100,0 ml/min
Dispensing pump 2
:
OK
Options:
– No
– 1 to 9999.0 ml/min
0 s
0/1
30 s
P: 200,0 ml/min
+
0/1
100,0 ml/min
P: No

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pw 418

Table of Contents