17. Thermostop

18. Level 2

19. Water inlet 2
20. Dispensing
phase 2
Duration:
Rhythm:
No
Normal
Gentle
Gentle+
User defined:
Spin speed:
No
Normal
Drench
User defined 20 to 70 rpm
 Thermostop is locked when "No" is programmed in programme
stage 4. Heating.
Choose from the following options:
– No
With Thermostop "No" the heating phase starts as soon as the
minimum heat level is reached. The wash times 1 and 2 are
chronologically processed, without the required temperature
necessarily being reached.
– Yes
When Thermostop "Yes" is programmed, the heating phase also
begins when the minimum heating level is reached and then allows
Wash time 2 to run only when the required temperature is reached.
Wash time 2 always starts at the required temperature.
– Disinfection
When Thermostop "Disinfection" is programmed, the procedure is the
same as for "Yes". Additionally, after a drop in temperature of 3 °C
below the lowest permissible hysteresis value (e.g. in case of peak
load, refuelling, power cut), Thermostop is activated and Wash time 2
and Dispensing phase 2 have to run again.
Settings as for Level 1
Settings as for Water inlet 1
Settings as for Dispensing phase 1
0.15 to 59 sec.
0 to 99 min.
On:
2 to 99 sec.
Off:
2 to 99 sec.
Programming
147