Chapter 2
Functions and Operations during Measurement
2.
Press
The ZERO indicator illuminates and the current
measured value is registered as 0 (zero).
• When a zero reset is executed, the analog output becomes the voltage or current value at the center of
the two preset points. Analog output becomes roughly 0 V or 12 mA when focus is not set.
• The Zero Reset function can also be executed by supplying a ZERO signal to the 20-pole terminal
block.
■ Canceling zero reset
1.
Press and hold
The zero reset function can also be canceled by supplying a ZERO signal to the 20-pole terminal block.
ZW
2-16
User's Manual
key.
ZERO/
ZERO/ SET
SET
Setting focus p.4-14
20-pole terminal block p.4-2
ZERO input p.4-8
ZERORST/ ESC
ZERORST/
ESC
key for two seconds.
20-pole terminal block p.4-2