Omron ZW Series User Manual page 170

Displacement sensor, confocal fiber type
Hide thumbs Also See for ZW Series:
Table of Contents

Advertisement

Chapter 4
Timing Charts
■ Zero reset
Zero reset input
(ZERO)
Judgment output
(HIGH/PASS/LOW)
T7
Response time of input
T13
Zero reset input time
T14
Cancel time of zero reset input
● Explanation of operations
(1)
The zero reset input is turned ON.
(2)
After the zero reset input time, the zero reset input is turned OFF.
(3)
After the zero reset input is turned OFF, the zero reset is executed and the
judgment results reflected in the measurement results are output.
(4)
The zero reset input is turned ON.
(5)
After at least the cancel time of zero reset input has passed, the zero reset is
cancelled.
ZW
4-42
User's Manual
(1)
(2)
T13
ON
OFF
Item
(3)
(4)
T7
T14
Minimum
2 msT0
50 ms
1 s
(5)
Maximum
3 msT0u2
0.8 s
-

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zw-s20Zw-s40

Table of Contents