■ Output format
● When the measured value is output
Outputs the measured value as a 21-bit binary number (2's complement).
(Example1)
When the measured value is "+1.23456" (The number of digits after the decimal point is
the default (5 digits).)
123456 (decimal) o 000011110001001000000 (binary)
(Example2)
When the measured value is "-1.23456"
-123456 (decimal) o 111100001110111000000 (binary)
When multiple tasks are output continuously, the currently output task number is output in the
BINARY_OUT output.
Checking Information p.3-47
Display
ESC
SET
ESC
SET
LIT
H
L
RUN
RUN
Description
Press
or
keys to select either of "TASK1"
and press
key.
ZERO/
ZERO/ SET
SET
Enable TASK1 binary output.
The current setting value is displayed on the sub-
display.
Press
/
keys to enter the editing mode, and the
sub-display blinks.
Select "ON" and press
ZERO/
ZERO/ SET
SET
RUN
RUN
Press
key for two seconds to enter the RUN
FUN
FUN
L
TEACH
TEACH
mode.
Chapter 4
Settings for I/O
key.
ZW
User's Manual
4-23