Troubleshooting - Omron ZW Series User Manual

Displacement sensor, confocal fiber type
Hide thumbs Also See for ZW Series:
Table of Contents

Advertisement

Chapter 7

Troubleshooting

Troubleshooting
This section describes countermeasures for temporary hardware problems.
Check the items below before sending the hardware for repair.
Error type
Starting error Device restarts during
Display error
Measuremen
t error
ZW
7-2
User's Manual
Problem
The power supply device is
operation.
not connected correctly.
The power supply capacity is
insufficient.
The main display
The target to measure is not in
remains on "- - - - - -."
the measuring range.
TIMING is not input.
The trigger level is not
appropriately set for self-
trigger.
Refer to the "The measured values fluctuate." and "The logical
beam does not come out of the Sensor Head." items below.
The main display
A system error has occurred.
becomes "SYSERR."
Abnormal distances
Such phenomena are
are displayed in areas
characteristic of the sensor.
clearly outside the
measuring range.
The measured values
The average count is not set
fluctuate.
correctly.
The target to measure and the
Sensor Head are vibrating.
The fiber cable edge or the
lens surface of the Sensor
Head is dirty.
The connection between the
Sensor Head and the
controller or the connection
with the extension fiber cable
is not normal.
The fiber cable is
disconnected.
The Sensor Head lens is
broken.
Water and/or oil droplets are
attached.
Probable cause
Possible countermeasure
Check if the power supply
device conforms to the power
supply specifications.
Place the target to measure in
the measuring range.
Enter a TIMING signal.
Set the self-trigger level to an
appropriate value.
Identify the cause of the error
based on the error code
displayed on the sub-display
and take an appropriate
action.
• Check the target to mea-
sure and the measuring dis-
tance.
• Lowering the expose time
setting value may improve
the situation.
Set the average count
correctly.
Implement a vibration-control
countermeasure.
Clean the surface.
Check the fiber cable
connections.
Replace the fiber cable.
The Sensor Head needs to be
repaired.
Please contact an OMRON
branch or sales office.
For sensor head repair, return
as a set with the Calibration
ROM.
Perform air purging and so
forth to remove the droplets.
Page
p.6
p.1-8
p.6-4
p.4-2
p.4-8
p.3-32
-
p.7-5
p.3-3
p.3-16
-
p.9
p.1-16