Appendix D: System Event Messages
2.06 Solvent Tank Empty
Description:
Cause(s):
Solution:
2.07 Internal Spillage
Description:
Cause(s):
Solution:
2.09 Misaligned Ink Jet
Description:
Cause(s):
Solution:
Linx 4900 Operating Manual
The solvent in the solvent tank has fallen below the
minimum level.
Solvent-level sensor has been indicating low ("3.04
Solvent Low" warning) for approximately 12 hours.
This time limit prevents the solvent from running out
completely, if the user fails to refill the solvent reservoir
following a system warning "3.04 Solvent Low". This
failure occurs only when the jet is running since the jet
cannot normally be started when the solvent is low.
Refill with solvent. See Chapter 7, 'Diagnostics and
Maintenance'.
An internal spillage has occurred, causing the printer to
stop and shut down the jet.
Overflow in ink or solvent reservoir due to incorrect
refilling.
Leak within the ink or solvent system.
Switch off the printer, and contact your local Linx
distributor.
Under normal operating conditions, the gutter sense
circuit detects the presence of ink flow in the gutter. If
ink flow is not detected for any reason (for example, a
misaligned jet), the jet will shut down. Absence of ink in
the gutter is detected within approximately 10 seconds.
Partly blocked nozzle.
Blocked gutter.
Contaminated ink.
Mechanical misalignment of the nozzle.
Obstruction of the jet through the charge electrode.
Clean the printhead; perform the Nozzle Clear and
Nozzle Flush functions. See Chapter 7, 'Diagnostics and
Maintenance'.
If the failure persists, contact your local Linx distributor.