iQube2® Junction Box
14. Attach the home run cable to the top side connector.
15. Install the iQube2 junction box into the forklift scale, using Loctite on the mounting screws.
16. Open the calibration access switch cover on the junction box, set switch to the On position.
17. Plug in the power cable, and turn on the communication power box.
18. Calibrate the unit using Revolution software.
19. Connect the load cell cables to each side.
20. Connect the coiled interface cable to the top of the junction box.
21. Align the iQube2 junction box with the bolt holes in the scale and use an Allen wrench to tighten.
22. Place the cover plate in place and secure with a bolt and washer and seal the unit.
7.2

Download the Serial Number to the Junction Box

1. Select the Serial Number tab to download the serial number of the scale using Revolution while in EZ Setup mode.
Figure 7-5. Serial Number Tab
2. Select the Get Current Serial Number button to get the current serial number.
Figure 7-6. Enter Current Serial Number
© Rice Lake Weighing Systems ● All Rights Reserved