6.0

Load Cell Replacement and Flexure Troubleshooting

This section describes procedures for replacing a load cell. The CLS uses Rice Lake's load cell, PN 125543.
The following instructions must be followed exactly to allow for seamless and easy load cell replacement.
Take all necessary safety precautions when installing or replacing the scale parts including wearing safety
WARNING
shoes, protective eyewear, and using the proper tools.
6.1

Required Tools for Replacing a Load Cell

The following list of tools is necessary for replacing a load cell on the CLS-M scale. Ensure that you have these tools handy.
Adequate light is necessary to change the load cell. Try to position the forklift close to a good source of natural light
Note
or if not possible, have a good source of lighting available.
Rice Lake
Part #
Item Description
96196
Modified box wrench
Crescent wrench
3/4" socket wrench, with extensions
ball-peen hammer
1-1/8" wrench for overload stop
Chisel
Allen wrench for overload stops
Torque wrench
Pry bar
Table 6-1. Required Tools for Replacing a Load Cell