Connect the Coiled Interface Cable to Junction Box

Loop Clamp Assembly
(PN 150720)
Used with Scale Cover
Assembly PN 97118
Scale cover
assembly
1. Loosen the bolt holding the cover to the scale assembly and remove cover.
2. Assemble loop clamp kit to the interface cable.
3. Route the interface cable through clips on backside of carriage toward middle. For proper interface cable routing,
tighten clips; the other end of the cable connects to the power/communication box
4. Push the interface cable through the hole in the scale and connect it to the junction box.
5. Position the scale cover assembly and the loop clamp assembly on the scale and secure with the bolt and washer.
After successful installation
page
38), replace the cover on the scale assembly and secure with bolt and washer.
Note
2.6

Install Forks onto Scale Assembly

1. Align a fork to the center of the scale assembly making sure it is over the top of the assembly
2. Lift the carriage slightly to set the fork, and then slide the fork to the side of the scale; let it stop in the second notch
from the end and latch it in place; repeat process for other fork, sliding it the opposite direction on the scale
For accurate weighing it is recommended to leave forks at the second notch from the outside edge of the scale.
Note
Interface cable
Figure 2-6. Connect Interface Cable
(Section 2.0 on page 5
and
Fork
Last Botch Open
Figure 2-7. Fork Attachment
Bolt
Washer
Loop
Clamp
Washer
Nut
Loop Clamp Assembly
Used with Scale Cover
Assembly PN 162340
(Section 3.0 on page
Section 3.0 on page
12) and calibration
© Rice Lake Weighing Systems ● All Rights Reserved
Scale Base Installation
(PN 167250)
12).
(Section 5.0 on
11