Live Weight Data - Rice Lake CLS-M Installation & Service Manual

Cargo lift scale
Hide thumbs Also See for CLS-M:
Table of Contents

Advertisement

CLS-M Installation/Service Manual
4.4

Live Weight Data

Also refer to this section to check scale for accuracy.
Note
The second tab is the Live Weight Data screen. This screen is used during calibration of the scale to verify the weight values.
The Live Weight Data screen will only operate with the calibration switch in the closed position.
1. Press
and select the Live Weight Data tab.
2. Select the Live Weight Data tab.
Item No.
1
Weight Data Packet – output formats/displays the output protocol of the CLS
2
Auto Refresh – check to start continuous streaming of data in the weight data packet
3
Zero – used to zero the scale
4
Weight – displays value of weight on scale
5
Pitch Angle – angle of the scale in a front to back direction
6
Roll Angle – angle of the scale in a side to side direction
7
Cell 1 mV (raw)
8
Cell 2 mV (raw)
9
Units, Mode, Serial Number – print string test boxes for confirmation of the weight data package
Weight data packet screen shows output format of CLS. Other displays include weight, pitch angle, roll angle, cell 1
and 2mV
(Section Figure 4-30. on page
Note
held device when attached through Bluetooth.
To start streaming data, check the auto refresh box. If not checked, the refresh button needs to be selected after each
change of weight to the load cell.
www.RiceLake.com
30
Visit our website
Figure 4-30. Live Weight Data Tab
Description
Table 4-1. Revolution Live Weight Data Item Descriptions
33). This is the information that will be sent to the customer-supplied hand-