1.2.2

Forklift Battery and CLS Installation

Take into consideration that the indicator power source is connected directly to the battery of the forklift. Most
typical is 12 volts for propane, gas and diesel forklifts.
CAUTION
12 volt systems must have a negative ground, ensure the forklift has a negative ground electrical system. The
CLS cannot operate on a positive ground forklift. Refer to the forklift manual to verify grounding requirements.
Standard CLS scales use 9-36 V power supply for use on 12 V batteries. Install the following for electric system forklifts:
PN 166162 – DC-DC Converter, CLS
PN 166161 – Power Line Filter, CLS (for static protection)
1.3

Power/Communication Box Introduction

The Power/Communication box transmits data between the scale and the hand-held device. The Mac ID label is used to pair
the CLS Bluetooth
interface with the hand-held device supplied by the customer.
®
1.4

Power/Communication Connection to Junction Box

The Power/Communication box receives data from the junction box through the Interface Cable.
Figure 1-3. Power/Communication Box Schematic (PN 153616)
Figure 1-4. Interface Cable – Power/Communication Box to Junction Box