Reading Data in Live Weight Screen

1. Once calibration is complete, select the Live Weight Data tab.
When moving the calibration switch in and out of calibration mode, it may take a few seconds for the Weight
IMPORTANT
Data Packet and Weight window fields to update with accurate information.
The mV, Pitch and Roll Angle functions are active whether the scale is in calibration or normal weighing mode. If the sealing
switch is in calibration mode, the Weight may have held the last displayed weight value in memory. Move the sealing switch in
normal weighing mode to continue to use the Live Weight Data feature correctly.
2. Place the calibration switch into the closed position, toward the left-hand side of the junction box when standing in front
of the scale.
3. Test a known weight amount as specified in
Weight Data Packet values will update.
4. If scale is weighing correctly, carefully disconnect USB and replace the clear cover.
5. Swivel the cover plate back to the correct position and secure with the screw.
6. Upon successful installation and calibration, seal the carriage junction box and load cell for Weights and
Measurements approval.
7. Re-install the scale cover plate; the scale is now ready for use.
www.RiceLake.com
56
Visit our website