3.3

Power Cable Connection

Each installation is unique, depends on model and style of the forklift.
Do not connect the power cable to the power/communication box until battery connection and power hook-up is
CAUTION
complete.
The indicator power source is connected directly to the battery of the forklift. 12 volt systems are typical for
propane, gas and diesel forklifts.
12 volt systems must have a negative ground, ensure the forklift has a negative ground electrical system. The
CLS cannot operate on a positive ground forklift.
Refer to the forklift user's manual for further verification of grounding requirements.
The power/communication box draws its power from the forklift battery. After it is mounted, run the power cable along the
shortest path that provides protection for the cable (away from moving or hot objects and pinch points), to the forklift battery.
Secure the cable at several points with cable ties.
Cable is required to run inside the roll cage tubing, if there are access holes for this purpose, using fish tape. If the cable is run
through a hole in a tube or panel, be sure the cable is protected against chaffing
When routing cables, do not cover any existing labels on the forklift in compliance with OSHA regulations.
WARNING
Avoid running wires anywhere they could potentially be damaged.
IMPORTANT
* Do not let the cable touch or run along anything that gets very hot
* Keep the cable away from moving parts, including control linkages and fan blades
* Do not place the cable where it can be pinched by the compartment cover when closed
* Do not run the cable up against, or directly across the ignition wires
* Do not let the cable come in contact with engine fluids
* Secure the cable with cable ties at several points to prevent movement or loosening
* Inspect the cable often to ensure it has suffered no damage
Power cable must run inside
the overhead guard pillar.
Figure 3-6. Route Power Cable (PN 153616)
© Rice Lake Weighing Systems ● All Rights Reserved
Power/Communication Box Hardware Setup
.