Appendix A
Initialization LED Error Codes
Table A-14 lists the possible Initialization LED Error Codes that can exist when a fault condition occurs
during a UBA initial start-up.
LED Status
Red LED
Green LED
3 Flashes
OFF
5 Flashes
OFF
11 Flashes
OFF
12 Flashes
OFF
*
OFF
13 Flashes
14 Flashes
OFF
15 Flashes
OFF
*. Occurs when three (3) rapid flashes are present when unit is initially powered-up indicating an ICB failure.
If diagnostic LED status is different from
the Table A-14 listed states, contact JCM
Technical Support.
JCM Part No. 960-000097R_Rev. 3
Universal Bill Acceptor (UBA-1x-SS & x4-SS-SU)
Table A-14 ICB Initialization Errors
Error
ICB Module
ICB disabled or Cash Box is Active.
New Processor Board, or Calibration is correct. Re-cali-
Calibration
brate the Sensors (See "Calibration Procedures" on
page 6-4 in Section 6 of this Service Manual).
Intelligent Cash Box (ICB) Communications Error
ICB Module
(Failure Type 02).
Intelligent Cash Box (ICB) Check Sum Error
ICB Module
(Failure Type 07). Memory partially cleared.
Intelligent Cash Box (ICB) Installed with data from another
ICB Module
machine (i.e., data not cleared) (Failure Type 08)*.
Intelligent Cash Box (ICB) not initiated (Failure Type 09).
ICB Module
Memory not properly cleared.
Intelligent Cash Box (ICB) Module Error (Failure AF). No
ICB Module
ICB Module detected present on Validator.
A - 1 4
Causes and Solutions
© 2010, JCM American, Corporation
Troubleshooting