No. 3 Running Test; Table A-5 Bill Stacker Test Error Conditions; Table A-6 Uba Running Test Error Conditions - JCM GLOBAL UBA Series Operation And Maintenance Manual

Universal bill acceptor
Table of Contents

Advertisement

Appendix A
Stacker
Red LED
Condition
Status
Stacker
1 Flash
Full
Stacker
2 Flashes
Jam
Stacker
4 Flashes
Motor Lock
Cash Box
10 Flashes
Error
If diagnostic LED status is different from
the Table A-5 listed states, contact JCM
Technical Support.

No. 3 Running Test

The tests listed in Table A-6 detect the
UBA's operational condition. When the
test starts, the following operation is
continuously repeated.
UBA
Red LED
Condition
Status
Stacker Full
1 Flash
Stacker Jam
2 Flashes
JCM Part No. 960-000097R_Rev. 3
Universal Bill Acceptor (UBA-1x-SS & x4-SS-SU)

Table A-5 Bill Stacker Test Error Conditions

DIP Switch Block Settings
Green LED
Status
A Stacker Encoder Board failure may have occurred. Check all
harnesses and connectors. Exchange the Stacker Encoder
OFF
Board and/or CPU Board if required with a known good board.
Refer to Section 4 regarding Circuit Board Removal.
An Exit Sensor Board failure may have occurred. Check all har-
nesses and connectors. Exchange the Exit Sensor Board and/
OFF
or CPU Board if required with a known good board. Refer to
Section 4 regarding Circuit Board Removal.
Stacker motor may be defective. Change the motor if defective.
A Stacker Encoder Board failure may have also occurred.
Check all harnesses and connectors. Exchange the Stacker
OFF
Encoder Board and/or CPU Board if required with a known
good board. Refer to Section 4 regarding Circuit Board
Removal.
A Cash Box Sensor Board failure may have occurred. Check all
harness and connectors. Change the Box Sensor Board and/or
OFF
CPU Board if required with a known good board. Refer to Sec-
tion 4 regarding Circuit Board Removal.

Table A-6 UBA Running Test Error Conditions

DIP Switch Block Settings
Green LED
Status
A Stacker Encoder Board failure may have occurred. Check
all harnesses and connectors. Exchange the Stacker
OFF
Encoder Board and/or CPU Board if required with a known
good board. Refer to Section 4 regarding Circuit Board
Removal.
An Exit Sensor Board failure may have occurred. Check all
harnesses and connectors. Exchange the Exit Sensor
OFF
Board and/or CPU Board if required with a known good
board. Refer to Section 4 regarding Circuit Board Removal.
A - 6
Causes and Conditions
If neither the Red or Green LED lights, it
means the UBA is operating properly.
If the Red LED flashes, refer to Running
Test Error Conditions listed in Table A-6
to discover the probable error condition.
Causes and Conditions
© 2010, JCM American, Corporation
Troubleshooting

Advertisement

Table of Contents
loading

Table of Contents