Installation/Fitting

5 Installation/Fitting

5.1 Transport and Delivery

5.1.1 Scope of Delivery

The scope of delivery of the ISD connection box comprises:
5
5
the connection box
1 set of plug connectors
these operating instructions

5.1.2 Transport

The maximum weight of a packaged connection box is
approximately 5.5 kg.
Avoid vibration during transportation.
Avoid heavy impacts and blows.

5.1.3 Inspection on Receipt

After receiving the delivery, immediately check whether
the scope of delivery matches the shipping documents.
Danfoss will not honour claims for faults registered at a
later time.
Register a complaint immediately:
with the carrier in case of visible transport
damage.
with the responsible Danfoss representative in
case of visible defects or incomplete delivery.
24
®
VLT
ISD Connection Box Operating Instructions

5.2 Safety Measures during Installation

Always observe the safety instructions in 3 Safety
instructions during installation.
Pay particular attention to ensuring that the following
points are observed carefully:

5.3 Installation Environment

Environmental Conditions
The installation must provide the following environmental
conditions to allow the connection box to be operated
safely and efficiently.
Contact Danfoss if it is not possible to comply with these
environmental conditions.
®
MG75G102 - VLT
is a registered Danfoss trademark
installation may only be performed by qualified
personnel.
installation must be performed with due care and
attention.
all safety regulations and protective measures are
complied with, and the environmental conditions
are observed.
the documentation is read and understood.
The allowable operating ambient temperature
range is not exceeded.
The relative humidity is 5-85%, non-condensing
(according to IEC 60721-3-3).
The vibration level is ≤1 g/9.81 m/s
resonance excitation.
Unrestricted ventilation is available.
The maximum operating temperature is 40 °C. A
control cabinet climate control should be used if
necessary.