Digital Outputs (see wiring diagram for Remote Terminal Block)
Terminals
Connected function
IET / Controller Running Relay
J1:
Digital output with two voltage free contacts at one relay, configurable through P.013
for status indication.
- P.013: 0 = State of active faults (IET)
- Contacts rated for max. load of
- Contacts rated for min. load of 10 mA at
NC Normally Closed Contact
28,29
NO Normally Open Contact
30,31

Analog Speed Reference Input

Terminals
Connected function
+10 VDC Supply, isolated, stabilized, max. 2.7 mA
J1: 12
+15 VDC Supply, isolated, after 1.8 kohm, for Types AC003 - 030 and 039/044
±10 V
13
±20 mA Analog Current Speed Reference Input, Impedance 250 ohm
14
15
Common, isolated, for Voltage / Current Input
For Voltage Speed Reference Input: Jumper J4 in upper position (V IN, Default),
Current Speed Reference Input: Jumper J4 in lower position (C IN)
Refer to : P.009 Terminal Strip Analog Input Offset (e.g. for 4 to 20 mA)
Analog Output (see wiring diagram for Remote Terminal Block)
Terminals
Connected function
J1:
Note: P.012 -Terminal Strip Analog Output Source
10

Analog output

11
Regulator Common
Jumper J17 setting for type of signal output:
• voltage
• or current (0 or 4 - 20 mA)
On types 038/043 and 058-360 the current range
0 - 20 mA or 4 - 20 mA can be selected with the two
jumpers near the relay.
NOTE: The Analog output for current signal is a sink
3-8
3 - INSTALLATION
1 = State of Controller Running (0.5 s delay after start)
2 = State of Controller Running (not delayed)
3 = State of Network Communication ACTIVE
4 = Relay is energized when all start permissive conditions are met.
5 = Relay is energized when one or more alarms are active.
(see wiring diagram)
Analog Voltage Speed Reference Input, Impedance 50 kohm
P.010 Terminal Strip Analog Input Gain
P.011 Terminal Strip Analog Input Configure
(0 - 10 V)
max. 4 mA, Impedance 2.5 kohm
type and requires an externally mounted
isolated power supply
(max. 12V, min Σ R
2 A at 30 VDC or
2 A at 250 VAC, or 500 VA at cos ϕ = 0.4.
5 VDC.
in position V OUT,
in position C OUT
x 20 mA).
receiver
GV3000/SE
60 W at L/R = 7 ms, and
J17
V OUT
!
!
0-20mA
!
!
C OUT
!
!
4-20mA
10
=<500 ohm
11
Load
J1
Current Output
!
!
!
-
+
P/S
49'1327 e