Selection Of Non Ul/Cul-Inverters Gv3000E - Reliance electric GV3000/SE Instruction Manual

General purpose and vector drive
Table of Contents

Advertisement

Tab. 2-8c: Selection of non UL/cUL-Inverters GV3000E- for Motors from 15 up-to 200 kW
TECHNICAL DATA
TYPE
INVERTER
NOM.
GV3000U
CURRENT
(2 kHz)
V/Hz
Vec.
AC038-
38
32
AC043-
43
38
AC058-
63
45
AC070-
70
45
AC085-
85
59
AC106-
116
89
AC140-
140
89
AC170-
170
118
AC210-
210
152
AC240-
240
152
AC305-
305
210
AC360
360
250
DC360-
360
250
On GV3000E with RFI filter, specified in the table below, the HF emission limits of class A, group 1
nd
(EN 55011) in the 2
Generic Standard EN 50081-2. This is recommended if e.g. in industrial estates high power converters
and offices with sensitive consumers are connected to the same supply transformer.
For GV3000E above 100 A with built-in HF Filter for CE conformity refer to table 2-8d on next page.
TECHNICAL DATA
TYPE
INVERTER
GV3000E
NOM.
CURRENT
(2 kHz)
V/Hz
Vec.
AC038-
38
32
AC043-
43
38
AC058-
63
45
AC070-
70
45
AC085-
85
59
AC106-
116
89
AC140-
140
89
AC170-
170
118
AC210-
210
152
AC240-
240
152
AC305-
305
210
AC360
360
250
* see different versions as illustrated in Figure 2-1 (Number in brackets represents illustration number)
1) On GV3000E-AC170 the rated current of the built-in RFI-filter is 150 A.
If 90 kW motors are operated in open loop (V/Hz) regulation with 2 kHz switching frequency,
the separately mounted 270 A RFI-filter 839.70.66 must be used.
49'1327 e
MOTOR
BASIC VERSION
NOM.
POWER
400VAC
V/Hz
Vec.
Code
18.5
15
AA
22
18.5
AA
30
22
AA
37
22
AA
45
30
AA
55
45
AA
75
45
AA
90
55
AA
110
75
AA
132
75
AA
160
110
-
200
132
200
132-
AA
environment (industrial supply network) are met, as required in the past for the
MOTOR
VERSION with
NOM.
RFI FILTER
POWER
400VAC
V/Hz
Vec.
Code
18.5
15
AA-RFI
22
18.5
AA-RFI
30
22
AA-RFI
37
22
AA-RFI
45
30
AA-RFI
55
45
AA-RFI
75
45
AA-RFI
90
55
AA-RFI
external RFI-Filter
110
75
see chapter 5
132
75
160
110
200
132
2 - DESCRIPTION
SPECIFICATION NUMBERS (non cUL)
VERSION with
IP20
BRAKING UNIT
Part No.
Code
896.10.01
AA-DBU
896.11.01
AA-DBU
896.12.01
AA-DBU
896.13.01
AA-DBU
896.14.01
AA-DBU
896.15.01
AA-DBU
896.16.01
AA-DBU
896.17.01
AA-DBU
896.18.01
AA-DBU
896.19.01
AA-DBU
-
896.21.51
--
SPECIFICATION NUMBERS (non UL/cUL)
VERSION with
BRAKING UNIT and
* (1)
RFI FILTER*
(1) and (2)
Part No.
Code
896.10.21
AA-DBU-RFI
896.11.21
AA-DBU-RFI
896.12.21
AA-DBU-RFI
896.13.21
AA-DBU-RFI
896.14.21
AA-DBU-RFI
896.15.21
AA-DBU-RFI
896.16.21
AA-DBU-RFI
896.17.21 1)
AA-DBU-RFI
external RFI-Filter
see chapter 5
external Braking Unit DBU
for AC305/360
GV3000/SE
DC-BUS TERMINAL
* (2)
Part No.
Code
896.10.11
AA-DBT
896.11.11
AA-DBT
896.12.11
AA-DBT
896.13.11
AA-DBT
896.14.11
AA-DBT
896.15.11
AA-DBT
896.16.11
AA-DBT
896.17.11
AA-DBT
896.18.11
AA-DBT
896.19.11
AA-DBT
-
-
AA-DBT
AA-DBT
--
DC-BUS TERMINAL
Part No.
Code
896.10.31
AA-DBT-RFI
896.11.31
AA-DBT-RFI
896.12.31
AA-DBT-RFI
896.13.31
AA-DBT-RFI
896.14.31
AA-DBT-RFI
896.15.31
AA-DBT-RFI
896.16.31
AA-DBT-RFI
896.17.31 1)
AA-DBT-RFI
VERSION with
* (3)
Part No.
896.10.81
896.11.81
896.12.81
896.13.81
896.14.81
896.15.81
896.16.81
896.17.81
896.18.81
896.19.81
896.20.81
896.21.81
--
--
VERSION with
and RFI FILTER
* (1) and (3)
Part No.
896.10.91
896.11.91
896.12.91
896.13.91
896.14.91
896.15.91
896.16.91
896.17.91 1)
external RFI-Filter
see chapter 5
2-21

Advertisement

Table of Contents
loading