Regulator Card Layout For Type Gv3000E-Ac003 - 030 And 039/044; Regulator Card Layout For Type Gv3000E/U-Ac038/043 And 058 - 360 - Reliance electric GV3000/SE Instruction Manual

General purpose and vector drive
Table of Contents

Advertisement

Regulator Card Layout for Type GV3000E-AC003 - 030 and 039/044

+5V G N D
I PH W
I PH U
I PH V
Testpoints
X9
Flat ribbon
cable connector
X16
X8
X7
9 pole
10 pole
Regulator Terminal Block
NOTE: For access to jumpers J4, J17 or test pins on the Regulator board or mounting an option board
you need to remove the green plastic cover.
1. Disconnect, lock out, and tag all incoming power to the drive.
2. Wait five minutes for the DC bus capacitors to discharge.
3. Disconnect any wiring from the face of the drive.
4. Remove the cover as follows:
- Unscrew the attaching screw on the cover.
- Lift the cover and carefully take it out of the heatsink as far as the flat ribbon keypad cable will allow. This cable
connects the display with the Regulator board.
- Use a screwdriver to slide the cable out of the connector on the regulator board to completely detach the cover.
5. On 24 to 44 A drives only: Remove the front panel by unscrewing the two attaching screws.
For reattaching the cover proceed in the reverse order.

Regulator Card Layout for Type GV3000E/U-AC038/043 and 058 - 360

-15V +15V
GND
Test points
J2
J3
Flat ribbon cable connector
J7
10 pole rectangular
9 pole D-Shell
J8
J1
Regulator Terminal Block
49'1327 e
3 - INSTALLATION
-15V
+15V
J17
U OUT
C OUT
J4
U IN
C IN
X1
4.....
Analog Output:
Default: Voltage
+5V
IPHU IPHW
J16
Display
J17
U OUT
U IN
C OUT
C IN
Analog Output:
Default: Voltage
J2
1
X3
Flat ribbon cable
Analog Input:
Default: Voltage
Flat ribbon cable connector
Keypad
J4
0-20
4-20
Analog Input:
Analog Output Range:
Default: Voltage
Curr. Default: 4-20mA
GV3000/SE
.....25
Relay
3-5

Advertisement

Table of Contents
loading