Room temperature air (white arrows) enters
the lower portion of the dryer through a gap
formed behind the bottom of the lower service
panel. Therefore it is very important to raise
the bottom of the dryer by installing the feet
properly. This room air is drawn though
the heating system (gas burner or electric
element).
Heated dry air (dark arrows) is then drawn
up the heat duct mounted behind the rear
bulkhead and then into the drum.
As the dry heated air circulates in the drum it
picks up moisture from the wet clothes. The
more space around tumbling clothes for dry
heated air to come into contact with fabric, the
faster clothes will dry.
7.4 Cubic Liters,
Capacity
7.4
Motor
Thermo-protected against overload auto-reset
Air Flow
Cubic meters per minute exhausted from dryer
Tumbler
Revolution per minute
Rotation
Drum Turning, when viewed from the front
Heat Source
• Gas
Exhaust
Venting size
Makeup Air
Free opening
Static Pressure
Single unit exhausting, 4" round r

air iNTakE aND ExHauST

209 Liters
Electri
c
The moistened heated air is drawn down
through the lint filter, through the blower and
into the exhaust duct, where it is vented out of
the dryer and out of the building.
One washer load is a full dryer load
1/3 HP, 220 Volt, 50 Hz
6.1
m/m
4.7
m/m³ Electric 5.0 m/m³ Gas (A series)
50 RPM ± 1.5
Clockwise
220 - 240 Volt 50 Hz, 4600 watts,
20 amp fuse
• Single port burner 20,000 BTU/hr.
direct ignition, auto shut off, 10 amp fuse
10.2 cm (4")duct, rigid
(See installation i
with the dryer for additional information)
Requires 193 cm² per dryer pocket
Should not exceed
igid duct.
25 mm (1") Water Column (B series)
15 mm (.6") Water Column (A series)
or be less than 0" Water Column
3-2
Electric 6.5 m/m
Gas (B series)
³
³
duct
nstructions provided