rEMOvE TOP OF DrYEr

Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Open the control panel (See page 4-13).
2.
Remove three 1/4" hex head screws from
the back edge of the dryer top that secure
the top to the back of the dryer.
Three 1/4" Hex
Head Screws
3.
Lift up slightly on the rear of the top and
slide the top forward to release the secure
points on the front top edge of each side
panel.
4.
Use a prop to hold the top up. Do not strain
the wires in the harness still connecting the
top to the base of the dryer.
TECH TIP: If the secure points are loose it
can cause excess vibration.
Left Side
Secure Point
1.
2.
3.
Front Left
Secure Point
4-23
DiSCONNECT
DOOr SWiTCH
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
Remove the top of the dryer (See left
column).
The door switch connector is located on the
left side just below the top.
Use a flat blade screwdriver to release the
locking tab and separate the connector.
Door Switch
Connector