STaCk DrYEr TrOuBlESHOOTiNG GuiDE

Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
NOTE: Possible Cause/Tests MUST be performed in the sequence shown for each problem.
WON'T POWER UP.
(No display)
WON'T START CYCLE WHEN
CYCLE BUTTON IS PRESSED.
WON'T SHUT OFF
WHEN EXPECTED.
CONTROL WON'T
ACCEPT SELECTIONS.
WON'T HEAT.
Electrical Shock Hazard
1. Supply connections. See TEST #1.
2. Check harness connections.
3. Console electronics and housing assembly. See TEST #5.
4. Check for loose connections at Transformer.
1. If Select Cycle is flashing, make sure the door is completely
shut, and press and hold down a Cycle button for about
1 second.
2. See TEST #2.
3. See TEST #6.
1. PD Model: Console electronics and housing
assembly. See TEST #5.
2. CS Models: Timer cam not pressed on to timer body tight,
missing timer cam lug, excess cycles accumulated on timer,
timer motor or gear box stuck or broken timer.
3. MN Models: Timer stuck or damaged.
Keypad Assembly. See TEST #5.
1. Heater. See TEST #3.
2. Check harness connections.
3. Check installation.