Step Down Transformer - Electric Stack Dryers - Maytag MDE17CS Service Manual

New dependable care commercial single and stack gas and electric dryers 50 hertz models
Hide thumbs Also See for MDE17CS:
Table of Contents

Advertisement

Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.

STEP DOWN TraNSFOrMEr - ElECTriC STaCk DrYErS

Electric stack dryers will have a step down
transformer in the collar to provide power to
the control board and will not have an auto
transformer.
1.
Unplug dryer or disconnect power.
2.
Turn off gas supply to dryer.
3.
Remove the step down transformer
(See page 4-54).
Step Down
Transformer
In Electric
Stack Dryer
Electrical Shock Hazard
4.
Set ohmmeter to the R X 1 scale.
Set digital ohmmeters to lowest scale.
5.
Touch the meter test leads to the terminals
listed below:
Pins GY2 & BK3 = 27 Ω
Pins GY2 & WH1 = 45 Ω
Pins BK3 & WH1 = 74 Ω
All readings ± 5%
5-14