SPECIFICATIONS

These units are sold in multiple regions with different
requirements for measuring capacity. Below are a few
of the valid forms of measure posted on this product:
Dry Linen Capacity: A weight measure that reflects
a maximum load size that can be loaded into the dryer.
IEC Capacity: The capacity measure that represents
the maximum capacity of dry linens and textiles which
the manufacturer declares can be treated in a specific cycle.
CHECK YOUR VENT SYSEM FOR GOOD AIR FLOW
WARNING
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death
or fire.
Good air flow
Along with heat, dryers require good air flow to efficiently
dry laundry. Proper venting will reduce your drying times
and improve your energy savings. See Installation
Instructions.
The venting system attached to the dryer plays a big role
in good air flow.
Service calls caused by improper venting are not covered
by the warranty and will be paid by the customer, regardless
of who installed the dryer.

USE AUTOMATIC DRY CYCLES FOR BETTER FABRIC CARE AND ENERGY SAVINGS

Use the Automatic Dry cycles to provide the most energy savings and enhanced fabric care from the dryer. During Automatic Dry
cycles, drying air temperature or moisture level are sensed in the load. This sensing occurs throughout the drying cycle and the
dryer shuts off when the load reaches the selected dryness.
With Timed Dry, the dryer runs the amount of time set and sometimes results in shrinkage, wrinkling, and static due to over-drying.
Use Timed Dry for the occasional damp load that needs a little more drying time or when using the drying rack.
4
Fire Hazard
3LMEDC315FW
Models
3LMEDC415FW
Rated Voltage
Rated Frequency
Rated Current
Dry Linen Capacity
(Maximum)
IEC Capacity
Height
Width
Depth
706 mm (27
To maintain good air flow:
■ Clean your lint screen before each load.
■ Replace plastic or foil vent material with 102 mm (4")
diameter heavy, rigid vent material.
Use the shortest length of vent possible.
■ Use no more than four 90° elbows in a vent system;
each bend and curve reduces air flow.
Good
■ Remove lint and debris from the exhaust hood.
■ Remove lint from the entire length of the vent sys-
tem at least every 2 years. When cleaning is com-
plete, be sure to follow the Installation Instructions
supplied with your dryer for final product check.
■ Clear away items from the front of the dryer.
4KMEDC215FW
4KMEDC315FW
4KMEDC415FW
4KMEDC425FW
220–240 V 2N~
220–240 V 2N~
50 Hz
60 Hz
20 Amps
20 Amps
15 kg (33 lb)
15 kg (33 lb)
7 kg (15 lb)
7 kg (15 lb)
1067 mm (42")
1067 mm (42")
737 mm (29")
737 mm (29")
")
706 mm (27
13
16
102 mm
4"
Better
")
13
16