Introduction
When  configuring  the  overall  system  using  the  CRS‐305  RMI  and  CRS‐316  TMI  modules, 
however,  you  must  be  careful  to  avoid  networking  loops.  For  example,  either  of  the 
following configurations is supported: 
 
Configuration #1:   
 
o Connect  port  "1"  of  each  Network  Processor  to  the  appropriate  RMI/TMI Modem 
side "Ethernet" port. 
 
o Connect the traffic data to the CRS‐316 User side "Ethernet" port. Connect port "2" 
of the primary NP to port "2" of the backup NP via a crossover cable. 
 
o No other connections are required for NP ports "3" and "4". 
 
Configuration #2:   
 
o Connect  port  "1"  of  each  Network  Processor  to  the  appropriate RMI/TMI Modem 
side "Ethernet" port. 
 
o Connect  the  traffic  data  to  the  CRS‐316  User  side  "Ethernet"  port,  as  per 
Configuration #1. 
 
o Connect  port  "2" of  the  primary  NP  and  port  "2"  of  the backup  NP to  a  common 
Ethernet  switch,  which  in  turn  shares  a  connection  to  an  external  network 
management device.   
 
o Use  the  external  network  management  device  to  monitor  both  modems  and  to 
make configuration changes to the primary modem. 
 
Other variations of the above configurations are possible.  However, a configuration that is 
not  allowed  is  the  connection  between  the  two  NPs  via  a  crossover  cable  while  also 
connecting both NPs to a common external switch.  This would result in a networking loop.   
 
2. CRS‐311  with  4‐Port  (Multi‐port)  Ethernet:  The  CRS‐311,  using  SLM‐5650/5650A  modems 
equipped  with  the  optional  Network  Processor  (NP)  Interface  Module,  may  be  configured 
with the CRS‐505 RMI and CRS‐515 TMI for multi‐port (1 to 4 ports) Ethernet traffic. Figure 
1‐6 shows the block diagram for this configuration. 
 
Note the following restrictions, depending on the Ethernet traffic mode employed:  
 
In  Ethernet  Router  Mode,  Ethernet  "Port  1"  on  the  CRS‐311  must  be  used  as  a 
minimum.  This  is  a  mandatory  requirement,  since  "Port  1"  on  the  CRS‐311  RMI/TMI 
allows the modems to share parameters. Optionally, "Port 2" through "Port 4" can be 
used, as needed, for additional user traffic connections. 
 
In  Ethernet  Bridge  Mode,  Ethernet  "Port  2"  through  "Port  4"  on  the  CRS‐311  can  be 
used. However, "Port 1" MUST NOT be used, since "Port 1" is designated specifically for 
Ethernet Router Mode. 