CRS-311 1:1 Redundancy Switch
Cables and Connections
3.3.6
Ethernet Data Traffic Connections – CRS-311 to Modems
3.3.6.1

Ethernet Bridge Mode Data Traffic via the Optional GbE Interface

When  the  SLM‐5650/5605A  modems  are  equipped  with  the  optional  single‐port  10/100/1000 
BaseT (GbE) Interface Module, Single‐Port Ethernet Bridge Mode is possible: 
 
Configuration 'A' – Referring to  Figure 3‐17, when the CRS‐311 is configured with the 
CRS‐306  or  CRS‐307  RMI  and  CRS‐316  or  CRS‐336  TMI,  connect  and  secure  all 
PP/CAT5FF3FTGY CAT5 Data Cables as follows:  
 
o From  the  RJ‐45  connector  labeled  "J5"  on  the  RMI  or  TMI,  to  the  RJ‐45 
 
Configuration  'B'  –  Referring  to  Figure  3‐18,  when  the  CRS‐311  is  configured  with  the 
CRS‐505  RMI  and  CRS‐515  TMI,  connect  and  secure  all  PP/CAT5FF3FTGY  CAT5  Data 
Cables as follows: 
 
o From  the  RJ‐45  connector  labeled  "Port  2"  on  the  RMI  or  TMI  to  the  RJ‐45 
 
 
 
3.3.6.2
Ethernet Bridge Mode Data Traffic via the Optional Network
Processor (NP) Interface
When  the  SLM‐5650/5605A  modems  are  equipped  with  the  optional  multi‐port  Network 
Processor (NP) Interface Module, Multi‐Port Ethernet Bridge Mode is possible. 
 
Referring to Figure 3‐19, connect and secure all PP/CAT5FF3FTGY CAT5 Data Cables as follows: 
 
From the RJ‐45 connectors labeled "Port 2" through "Port 4" on the RMI or TMI, to the 
RJ‐45 connectors labeled "Port 2" through "Port 4" on the Redundant or Traffic Modem 
optional Network Processor (NP) Interface Module. 
 
 
connector  labeled  "J1"  on  the  Redundant  or  Traffic  Modem  optional  GbE 
Interface Module. 
connector  labeled  "J1"  on  the  Redundant  or  Traffic  Modem  optional  GbE 
Interface Module. 
Do  not  connect  to  Port  1  on  the  RMI  or  TMI  when  operating  in 
Single‐Port Ethernet Bridge Mode. 
 
Do not connect to "Port 1" on the RMI, TMI, or to Port "1" on the optional 
Network  Processor  (NP)  Interface  when  operating  in  Multi‐Port  Ethernet 
Bridge Mode. 
 