CRS-311 1:1 Redundancy Switch
Front Panel Operation
5.2.5 STORE/LD (Store or Load Configuration)
STORE/LOAD CONFIG:
STORE
LOAD
Use these submenus to store or load up to 10 different Switch configurations in the CRS‐311's
non‐volatile memory. These are configurations for the Switch itself; they do not affect the
connected Traffic or Redundant modems.
Use the ◄►arrow keys to select STORE or LOAD, and then press ENTER.
This feature is operational in LOCAL MODE ONLY. If you attempt to save or load a
configuration while in Remote Mode, the following message displays:
THE SWITCH IS CURRENTLY
IN REMOTE MODE!! (CLEAR)
5.2.5.1
(STORE/LD) STORE
STORE CONFIGURATION TO
LOCATION: 10
Once all desired configuration changes have been made, use the ▲▼arrow keys to select the
location to store the current configuration, and then press ENTER.
Locations 1 through 10 are available. If the selected location does not contain a previously
stored configuration, the action is confirmed as follows:
YOUR CONFIGURATION HAS
BEEN STORED!
Press ENTER or CLEAR to return to the previous menu. If, however, the selected location
contains a previously stored configuration, you are alerted to this state as follows:
WARNING!
LOC 10 CONTAINS
DATA!
OVERWRITE?
Use the ◄►arrow keys to select NO or YES, and then press ENTER. Selecting YES overwrites the
selected location's existing configuration.
(PRESS ENTER)
(ENTER)
(ENTER)
NO
YES