CRS-311 1:1 Redundancy Switch
Front Panel Operation
Replace defective power supply module; 
 
If the second power supply module is not needed, you can mask this alarm. 
 
SWITCH ALARM: RM PROBLEM
RM I/O TIMEOUT
SWITCH ALARM: MODEM COMMS
PROBLEM, TRAFFIC MODEM
 
These Switch Alarm screen examples show that there are faults – communication has been lost to 
the Redundant or the Traffic Modem; accordingly, the front panel "Unit Status" LED indicator is 
lit RED. 
 
Suggested corrective actions include:  
 
Check cable connections.  
See Chapter 3. CABLES AND CONNECTIONS. 
 
Check cable operation. 
Ensure  the  cables  are  OK  by  swapping  them  with  others.  For  cable  information  refer  to 
Chapter 3. CABLES AND CONNECTIONS and Appendix A. CABLE DRAWINGS. 
 
Check modem configurations. 
See  Chapter  4.  MODEM,  RMI/TMI,  AND  SWITCH  CONFIGURATION  and  the  pertinent 
modem's Installation and Operation Manual. 
 
SWITCH ALARM:
MGC refused, cpde: 12 TFT
 
This  Switch  Alarm  screen  example  shows  that  there  is  a  fault  –  here,  COMMs  are  good  to  the 
Redundant  Modem,  but  the  configuration  of  the  Traffic  Modem  cannot  be  configured  into  the 
Redundant Modem. The front panel "Unit Status" is lit RED. 
 
Suggested corrective actions include:  
 
Ensure  that  the  most  capable  modem  (latest  hardware  revision,  firmware  version,  FAST 
options, installed options e.g. Turbo card) is set up as the Redundant Modem. 
 
The  code  indicates  the  parameter  within  the  modem's  "MGC"  (Global  Configuration) 
remote  command/query  configuration  string  that  is  causing  the  Redundant  Modem  to 
refuse it. 
 
 
 
‐OR‐ 
 
RM PROBLEM
5–14
Revision 7
MN/CRS311.IOM

Advertisement