Ethernet Bridge Mode Configuration Via Optional Network Processor (Np) Interface; Ethernet Bridge Mode Configuration Via Optional Gbe Interface - Comtech EF Data CRS-311 Installation And Operation Manual

1:1 redundancy switch, accessory product for use only with comtech ef data cdm-qx/qxl and slm-5650/5650a modems (modem firmware and hardware requirements apply)
Table of Contents

Advertisement

CRS-311 1:1 Redundancy Switch
Modem, RMI/TMI, and Switch Configuration
4.2.4.2.3
Ethernet Bridge Mode Configuration via Optional Network
Processor (NP) Interface
Ethernet  Bridge  Mode  redundancy,  when  using  SLM‐5650/5650A  modems  equipped  with  the 
optional Network Processor (NP) Interface, is provided by a single IP address scheme.  
 
Follow these steps to verify Single IP Address Mode on the Online Modem: 
Step
Task
From the SLM-5650A front panel, navigate to Config: Remote
1
Option Card Addr
2
Verify that the Mode appears as Single.
 
Follow these steps to verify Single IP Address Mode on the Offline Modem: 
Step
Task
From the SLM-5650A front panel, navigate to Config: Remote
1
Option Card Addr
2
Set the Traffic IP Address of the Online Modem only.
3
Verify that the Traffic IP Address also appears on the Offline Modem.
 
In Ethernet Bridge Mode, the CRS‐311 will keep the Online Modem's Ethernet Ports 2‐4 turned 
on.  The  CRS‐311  will  keep  the  Offline  Modem's  Ethernet  Ports  2‐4  turned  off.  The  traffic  IP 
address is only accessible on the Online Modem; there is NO access to the Offline Modem.  
 
Furthermore,  in  Ethernet  Bridge  Mode,  the  parameter  backup  mechanism  is  unsupported; 
therefore, you must make sure that all parameters match in the Online and Offline modems. 
 
See  the  SLM‐5650  or  the  SLM‐5650A  Installation  and  Operation  Manual  for  detailed 
configuration information. 
4.2.4.2.4

Ethernet Bridge Mode Configuration via Optional GbE Interface

Ethernet  Bridge  Mode  redundancy,  when  using  SLM‐5650/5650  modems  equipped  with  the 
optional 10/100/1000 Base‐T (GbE) Interface, is provided by a Single IP Address scheme.  
 
To configure the SLM‐5650/5650A for Ethernet Bridge Mode 1:1 redundancy, for each modem 
enter a unique IP Address for the optional 10/100/1000 Base‐T (GbE) Interface Module that is 
on the same subnet: 
 
 
See  the  SLM‐5650  or  the  SLM‐5650A  Installation  and  Operation  Manual  for  detailed 
configuration information. 
Network Proc.