Comtech EF Data CRS-311 Installation And Operation Manual page 26

1:1 redundancy switch, accessory product for use only with comtech ef data cdm-qx/qxl and slm-5650/5650a modems (modem firmware and hardware requirements apply)
Table of Contents

Advertisement

CRS-311 1:1 Redundancy Switch
Introduction
CRS‐281  (70/140 MHz IF) with Type 'BNC' (75Ω) connectors 
 
CRS‐281L (L‐Band IF) with Type 'N' (50Ω) connectors 
 
Two CRS‐281x switch modules are compatible for use with the SLM‐5650/5650A modem: 
 
CRS‐281 (70/140 MHz IF) with Type 'TNC' (50Ω) connectors. 
 
CRS‐281L (L‐Band IF) with Type 'N' (50Ω) connectors. 
 
The SLM‐5650/5650A modem permits simultaneous operation of the Tx IF and Rx IF 
bands  at  70/140  MHz  and  L‐Band  frequencies,  independent  of  one  another.  If  you 
 
want  the  Tx  and  Rx  to  be  of  different  IF  bands,  the  CRS‐281x  module  must  be 
selected based on the Tx IF band. An external splitter is then used for the Rx IF band 
when that side differs from the Tx IF band – see Figure 3‐19 and Figure 3‐20 in Sect. 
3.3.6 IF Connections – User to CRS‐281x to Modems for configuration examples. 
 
See  Sect.  1.3.6  CRS‐281x  IF  Switch  Modules  and  Sect.  1.4.2  CRS‐281x  IF  Switch  Module 
Specifications for more information on these switch modules and their specifications. 
 
CRS‐351 Option: Where protection of the overhead  signals (backward alarms, audio ESC, data 
ESC, etc.) is desired, the CRS‐351 Overhead Module may be added. 
 