Comtech EF Data CRS-311 Installation And Operation Manual page 141

1:1 redundancy switch, accessory product for use only with comtech ef data cdm-qx/qxl and slm-5650/5650a modems (modem firmware and hardware requirements apply)
Table of Contents

Advertisement

CRS-311 1:1 Redundancy Switch
Serial-based Remote Product Management
Arguments for
Command
Command or
Parameter Type
(Code and
Response to
qualifier)
Restore Holdoff
RSH=
2 bytes, numerical
Time
Switch Alarm
SAM=
1 byte, numerical
Mask
Switch Global
SGC=
29 bytes, numerical Command or Query.
Configuration
Switch ID
SID=
24 bytes, ASCII
Serial Number
N/A
9 bytes, numerical
Software Revision N/A
5 bytes, numerical
Description of Arguments
(Note that all arguments are ASCII numeric codes:
i.e., ASCII codes between 48 and 57)
Query
Command or Query.
The restore holdoff time is the delay when auto mode prepares to
return a modem (previously faulted, now good) back online due to a
different Traffic Modem's failure:
01-99 = # of seconds after offline Traffic Modem lost its fault before
it is put back online..
Command or Query.
x indicates the Switch alarm mask:
0 = no faults masked
1 = PSU-A faults masked
2 = PSU-B faults masked
Global configuration of the Switch, in the form:
OasssssssssBNNbbrrMSAssssssss, where:
O = Operating Mode – same as OPM (1 bytes)
a = Active Modem – same as ACT for TM (1 byte)
s = 9 spare bytes
B = Bridge/Backup State – same as BBU (1 byte)
NN = always 01 for the 311
bb = Backup Holdoff Time – same as BKH (2 byte)
rr = Restore Holdoff Time – same as RSH (2 byte)
M = Modem Alarm Mask – same as MAM (1 byte)
S = Switch Alarm Mask – same as SAM (1 byte)
A = Audio Alarm Mask – same as AAM (1 bytes)
s = 8 spare bytes
Command or Query.
A user-defined Switch ID, which is a fixed length of 24 characters.
Valid characters include:
Space ( ) * + - , . / 0-9 and A-Z.
Query only.
Unit returns its 9-digit serial number.
Example: SNO=176512523
Query only.
Unit returns the value of internal software revision installed in the
unit, in the form x.x.x
Example: SWR=1.0.1 (indicating Version 1.0.1)
Response to Command
(Target-to-Controller)
RSH= (message OK)
RSH? (received OK, but
invalid arguments found)
RSH* (message OK, not
permitted in current mode)
SAM= (message OK)
SAM? (received OK, but
invalid arguments found)
SAM* (message OK, but not
permitted in current mode)
SGC= (message OK)
SGC? (received OK, but
invalid arguments found)
SGC* (message OK, but not
permitted in current mode)
SID= (message OK)
SID? (received OK, but
invalid arguments found)
SID* (message OK, but not
permitted in current mode)
N/A
N/A
6–13
Revision 7
MN/CRS311.IOM
Query
Response to query
(Code and qualifier)
(Target-to-Controller)
RSH?
RSH=xx
(see description of
arguments)
SAM?
SAM=x
(see description of
arguments)
SGC?
SGC=OasssssssssBNNbbrr
MSAssssssss
(see description of
arguments)
SID?
SID=xxxxxxxxxxxxxxxxxxxxx
xxx
(see description of
arguments)
SNO?
SNO=xxxxxxxxx
(see description of
arguments)
SWR?
SWR=x.x.x
(see description of
arguments)