CRS-311 1:1 Redundancy Switch
Serial-based Remote Product Management
characters. Control and status information is transmitted in packets of variable length, in accordance with the structure and protocol 
defined in later sections. 
6.2

Interface Overview

6.2.1 EIA-485
For applications where multiple  devices are to be monitored and controlled, a full‐duplex (4‐wire plus ground) EIA‐485 is preferred. 
Half‐duplex  (2‐wire  plus  ground)  EIA‐485  is  possible,  but  is  not  preferred.  In  full‐duplex  EIA‐485  communication,  there  are  two 
separate, isolated, independent, differential‐mode twisted pairs, each handling serial data in different directions.  
 
It is assumed that a 'Controller' device (a PC or dumb terminal) transmits data in a broadcast mode via one of the pairs. Many 'Target' 
devices are connected to this pair, and all simultaneously receive data from the Controller. The Controller is the only device with a line‐
driver connected to this pair; the Target devices have only line‐receivers connected. 
 
In  the  other  direction:  On  the  other  pair,  each  Target  has  a  Tri‐State  line  driver  connected;  the  Controller  has  a  line‐receiver 
connected. All the line drivers are held in high‐impedance mode until one – and only one – Target transmits back to the Controller. 
Each  Target  has  a  unique  address;  each  time  the  Controller  transmits,  the  address  of  the  intended  recipient  Target  is  included  in  a 
framed 'packet' of data. All of the Targets receive the packet, but only one (the intended) will reply. The Target enables its output line 
driver and transmits its return data packet back to the Controller in the other direction on the physically separate pair. 
 
EIA‐485 (full duplex) summary: 
 
Two differential pairs – one pair for Controller‐to‐Target, one pair for Target‐to‐Controller. 
 
Controller‐to‐Target pair has one line driver (Controller), and all Targets have line‐receivers. 
 
Target‐to‐Controller pair has one line receiver (Controller), and all Targets have Tri‐State drivers. 
 
 
 
6–2