Remote Interface; Host Computer Remote Communications - Comtech EF Data Radyne RCS20 Installation And Operation Manual

M:n redundancy switch
Hide thumbs Also See for Radyne RCS20:
Table of Contents

Advertisement

RCS20 M:N Redundancy Switch
User Interfaces
4.3.4.6
REMOTE PORT TEST
This screen allows the user to send an ASCII test string out of the remote port.
4.3.4.6.1
Programming steps:
1.
Press <TEST> to send an ASCII string. The RCS20 will output ASCII characters 'Test' via remote
port each time <TEST> is pressed.
Key
S1
S2
S3
S4
Numeric Keypad
4.4

Remote Interface

4.4.1 Host Computer Remote Communications

The RCS20 has a dedicated RS-485 serial control port (Remote Port) for use with computer controlled
remote monitor and control systems. The Remote Port is a 9-Pin female 'D' sub connector J3 located at
the rear of the unit on the Switch Interface plug in module. The pinouts for the remote port are listed in
Section 5.
The Remote Port utilizes a binary protocol called Radyne Link Level Protocol (RLLP). RLLP is a multi-
drop packet-oriented protocol with handshaking, and is completely described in Appendix A. The remote
port supports standard UART asynchronous protocol with 8 data bits, no parity, and 1 stop bit (8N1) at 8
baud rates: 115200, 57600, 38400, 19200, 9600, 4800, 2400, and 1200.
REMOTE PORT TEST
Remote test will send ASCII characters 'Test' to remote port
each time the softkey labeled 'Test' is pressed.
<TEST>
Label
TEST
Press to send ASCII characters 'Test'.
---
N/A
---
N/A
RETURN
Press to cycle back to the SWITCH SYSTEM TESTS Screen 2.
---
N/A
4–63
<RETURN>