Comtech EF Data Radyne RCS20 Installation And Operation Manual page 81

M:n redundancy switch
Hide thumbs Also See for Radyne RCS20:
Table of Contents

Advertisement

RCS20 M:N Redundancy Switch
User Interfaces
4.3.2.24 REFERENCE DISTRIBUTION CONFIGURATION
This screen displays the configuration of the optional Reference Distribution Module Expansion Card
(RDM), located at the rear of the RCU20. The following are two configuration parameters for the RDM:
Fallback Programming - The fallback programming determines how the three frequency sources (External
A, External B, Internal) are automatically selected when any of the sources are removed.
Internal Reference Frequency - The internal frequency selects the frequency of the internal reference.
The line directly above the FALLBACK Line displays the current source with '***'. This line will display the
message NO RDM PRESENT if the RDM is not installed in the RCS20 system.
4.3.2.24.1
Programming steps:
1.
Press <FALL> to cycle to the RDM FALLBACK CONFIGURATION Screen for fallback
programming configuration.
2.
Press <FREQ> to cycle to the RDM INTERNAL REFERENCE CONFIGURATION Screen for
internal frequency reference configuration.
Key
Label
S1
FALL
S2
FREQ
S3
---
S4
NEXT
Numeric Keypad
---
REFERENCE DISTRIBUTION CONFIGURATION
NO RDM PRESENT
FALLBACK
: EXTA ONLY
INTERNAL FREQ : 10.0 MHZ
( '***' INDICATES CURRENT SOURCE)
FALL
FREQ
Press to cycle to the RDM FALLBACK CONFIGURATION Screen.
Press to cycle to the RDM INTERNAL REFERENCE CONFIGURATION Screen.
N/A
Press to cycle to the next screen.
N/A
4–49
NEXT
Function