Comtech EF Data Radyne RCS20 Installation And Operation Manual page 59

M:n redundancy switch
Hide thumbs Also See for Radyne RCS20:
Table of Contents

Advertisement

RCS20 M:N Redundancy Switch
User Interfaces
3. Select the desired demodulator acquisition delays for each prime channel (each demodulator
may be set to a different time delay if desired).
4. Press <CLR> or <NEXT> to abort programming (no switch parameters changed).
5. Press <ENT> to load the information on the screen into the switch parameter table.
Key
Label
S1
S2
S3
---
S4
NEXT
Numeric Keypad
---
4.3.1.22 FORCE MANUAL BACKUP
This screen allows the user to switch prime channels into backup manually. Backup Channel 1 must be in
manual mode to force prime channels into backup. If a prime channel is configured for linked switching,
then switching the prime channel modulator only will also switch the demodulator. Multiple modems may
be set. These connections may be any of the following:
M - Modulator
D - Demodulator
U - Modem
4.3.1.22.1
Programming steps:
1. Press SET BU1 to switch prime channels to Backup Channel 1.
2. Press SET BU2 to switch prime channels to Backup Channel 2.
3. Press <CLR> or <NEXT> to abort programming (no switch parameters changed).
Press to move the blinking cursor to the left. Used to select the demodulator (labeled
DMD1 through DMD9) to which the acquisition time is to be changed.
Press to move the blinking cursor to the left. Used to select the demodulator (labeled
DMD1 through DMD9) to which the acquisition time is to be changed.
N/A
Press to cycle to the next screen.
Used to enter the acquisition time for the selected demodulator.
Press <CLR> or <NEXT> to abort programming (no switch parameters changed).
Press <ENT> to load the information on the screen into the switch parameter table.
FORCE <MANUAL> BACKUP
MODEMS:
1
2
M=MOD, D=DEMOD, U=MODEM
SET BU1
SET BU2
Function
3
4
5
6
7
8
BU1:
BU2:
NEXT
4–27
Revision 15
MN-RCS20 and CD-RCS20

Advertisement

Table of Contents
loading